120A Isolation Current Transformer For I - P Close Link Meter Testing Ratio 1 : 1
KE632x Isolation current transformer
KE632x series includes Isolation current transformer (ICT) range from single phase to three phase. With wide current range, it is perfect for the test of I-P close link meter.
Features:
- High accuracy through active electronic error compensation.
- Direct perforated installation
- Wide current dynamic range: 10mA --120A (Primary side)
- Output power: Max 60VA per phase
- When secondary measure open circuit or overload occurs, ICT will protect automatically and send out alarm signal
- Can realize local bypass through button
- With RS485 port, can realize remote control and status monitoring
Specifications:
| | KE6323 | KE6322 | KE6321 |
| Accuracy | 0.02 |
| Phase number | 3 | 2 | 1 |
| Nominal frequency | 50 Hz (45 … 55 Hz) or 60 Hz (54 … 66 Hz) |
| Primary current range | 10mA-120A |
| Ratio | 1:1 |
| Secondary current range | 10mA-120A |
| Ratio error(typical) | ±0.01% |
| Angle error(typical) | ±0.05min |
| Output power per phase (max.) | 60VA |
| Auxiliary power supply | Ac185V- 265V / 45Hz - 65Hz |

Our Exhibition in India Elecrama