On - site portable energy meter test equipment Three Phase with 100A clamp CT class 0.1
KE7303 Portable Three Phase On-site Electric Meter Tester
Accuracy : 0.1, Test method: clamp CT and terminal input. It's light and small, which is convenient for on-site test. And it can be used to test the error of three phase energy meters and field electrical parameters of power grid.
Product descriptions:
- Calibrate the error of all electricity energy meters, checking the constant of the energy meter
- Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter inthe same loop
- Can measure voltage, current, frequency, power, power factor and phase angle
- Simultaneous measure and display waveforms of three phase voltage and current
- Detectthe error change of the clamp automatically; ensure the accuracy stability ofthe clamp and the instrument in the long run.
- Measure ratio of CT, VA burden of the metering loop from VT and CT secondary terminals.
- Allocate clamp of 20A, 100A, 500A, 1000A to directly measure the comprehensive error
- Can measure 2nd – 51st harmonics of current and voltage
- Display vector diagram, verify the wiring
- Battery, test lead power or external power for choices
- Communicate with PC, download calibration data through USB flash disk, RS-232 or bluetooth
- Firmware can be upgraded through removed disk by users themselves
- Save and browse the testing data, data storage quantity is up to 1000 pieces.
Technical specifications:
Current measurement
Current range Terminal input 0.1A – 10A
Clamp input 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A
Accuracy Terminal input ±0.1%
Clamp input ±0.2%(5A), ±0.5% (others)
Harmonics 2nd- 51st
Voltage measurement
Voltage range 3 x (0V – 480V)
Accuracy ±0.1%
Harmonics 2nd- 51st
Accuracy of power measurement
Active power Terminal input ±0.1%
Clamp input ±0.2%(5A), ±0.5% (others)
Reactive power Terminal input ±0.1%
Clamp input ±0.2%(5A), ±0.5%(others)
Accuracy of energy measurement
Active energy Terminal input ±0.1%
Clamp input ±0.2%(5A), ±0.5%(others)
Reactive energy Terminal input ±0.1%
Clamp input ±0.2%(5A), ±0.5%(others)
Phase measurement
Phase range 0 -- 360°
Accuracy ±0.1°
Frequency measurement
Frequency range 45Hz – 65Hz
Accuracy ±0.05Hz
Pulse output
High frequency output(CH) 3.6 x 107 imp / kWh
Low frequency output(CL) 3.6 x 104 imp / kWh
Pulse input
Input channel 2
Input frequency Max. 100Hz
Others
Three power supply way:
Build-in rechargeable battery,
external power supply(DC adapter),
power through the tested terminal
Dimensions 154mm×249mm×58mm
Weight 1.3kg