Portable Three Phase Field Meter Tester for energy meter with 100A clamp CT class 0.1
KE7303 Portable Three Phase On-site Electric Meter Tester
Accuracy : 0.1, Test method: clamp CT and terminal input. It's light and small, which is convenient for on-site test. And it can be used to test the error of three phase energy meters and field electrical parameters of power grid.
Features:
- Calibrate the error of all electricity energy meters, checking the constant of the energy meter
- Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter inthe same loop
- Measure voltage, current, frequency, power, power factor and phase angle
- Simultaneous measure and display waveforms of three phase voltage and current
- Detectthe error change of the clamp automatically; ensure the accuracy stability ofthe clamp and the instrument in the long run.
- Measureratio of CT, VA burden of the metering loop from VT and CT secondary terminals.
- Allocate clamp of 20A, 100A, 500A, 1000A to directly measure the comprehensive error
- Measurethe 2nd – 51st harmonics of current and voltage
- Display vector diagram, judge the wiring right or wrong automatically
- Read the information of energy meter with barcode scanner (optional)
- Battery, test lead power or external power for choices
- Communicate with PC, download calibration data through USB flash disk, RS-232 or bluetooth
- Firmware can be upgraded through removed disk by users themselves
- Save and browse the testing data, data storage quantity is up to 1000 pieces.
Main specifications:
|
KE7303 |
Voltage measurement |
Voltage range |
3 x (0V – 480V) |
Accuracy |
±0.1% |
Harmonics |
2nd- 51st |
Current measurement |
Current range |
Terminal input |
0.1A – 10A |
Clamp input |
5A, 20A, 100A, 500A, 1000A, 2000A, 3000A |
Accuracy |
Terminal input |
±0.1% |
Clamp input |
±0.2%(5A), ±0.5% (others) |
Harmonics |
2nd- 51st |
Accuracy of power measurement |
Active power |
Terminal input |
±0.1% |
Clamp input |
±0.2%(5A), ±0.5% (others) |
Reactive power |
Terminal input |
±0.1% |
Clamp input |
±0.2%(5A), ±0.5%(others) |
Accuracy of energy measurement |
Active energy |
Terminal input |
±0.1% |
Clamp input |
±0.2%(5A), ±0.5%(others) |
Reactive energy |
Terminal input |
±0.1% |
Clamp input |
±0.2%(5A), ±0.5%(others) |
Phase measurement |
Phase range |
0 -- 360° |
Accuracy |
±0.1° |
Frequency measurement |
Frequency range |
45Hz – 65Hz |
Accuracy |
±0.05Hz |
Pulse output |
High frequency output(CH) |
3.6 x 107 imp / kWh |
Low frequency output(CL) |
3.6 x 104 imp / kWh |
Ppulse input |
Input channel |
2 |
Input frequency |
Max. 100Hz |
Others |
Power supply |
Build-in rechargeable battery,
external power supply,
power through the tested terminal
|
Dimensions |
154mm×249mm×58mm
|
Weight |
1.3kg |
|