Technical specification:
KE8103-10 | |
Number of meter position | 10 |
Accuracy | ±0.05% |
Voltage output | |
Output range (P-N) | 24V - 300V |
Output power of voltage | 2 x 250VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Current output | |
Output range | 1mA - 120A |
Output power of current | 2 x 500VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Phase output | |
Output range | 0 -- 360° |
Resolution | ± 0.01° |
Frequency | |
Output range | 45Hz - 65Hz |
Resolution | ± 0.01Hz |
Operation condition | |
Power supply | 220V±10%,50/60Hz±2Hz |
Temperature | -10°C -- +40°C |
Humidity | 35% -- 85%RH |
Wiring diagram