KE8102 Single Phase Energy Meter Testing Equipment
KE8102 has multiple switchable channels for current output, used for testing 2 or 3 elements single phase mechanical and electric meter, Number of meter position : 3-64
Features:
· Integrated / Separated aluminum alloy structure, lightand reliable, flexible choices
· The numberof meter positions can be chosen from 3 - 64
· Perfect alarming protective function, auto protection ofthe short circuit of voltage, the opencircuit of current, and overload.
· Full automatic, semi automatic and manual operationavailable
· Supporting bar code input, which increase the efficiencyof input
· Simultaneous test of the energy meters with same specification, different constant and different class.
· Auto mark locking increases the efficiency of test
· Forward and reverse active energy / forward and reversereactive energy error test
· Creeping and starting test
· Standard deviation, 24 hour variation test
· Influencing quantity test of voltage, frequency, harmonic
· Calibration and verification of energy constant
· Powerful computer management system, easy anduser-friendly
· Perfect database management makes the storage, searching,and viewing of the data possible, and the data can be converted and exported inother forms
· The testof open circuit for Neutral voltage (optional)
· Adopt multi-serial port system, realizing the parallelcommunication of computer andthe tested meters (optional)
Main Specification:
KE8102-48 | |
Number of meter position | 48 |
Accuracy | ±0.05% |
Voltage output | |
Output range (P-N) | 24V - 300V |
Output power of voltage | 1000VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Current output | |
Output range | 1mA - 120A |
Output power of current | 2000VA |
Resolution | Better than ± 0.01% |
Stability | Better than ± 0.02% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.3% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Phase output | |
Output range | 0 -- 360° |
Resolution | ± 0.01° |
Frequency | |
Output range | 45Hz - 65Hz |
Resolution | ± 0.01Hz |
Operation condition | |
Power supply | 220V±10%,50/60Hz±2Hz |
Temperature | -10°C -- +40°C |
Humidity | 35% -- 85%RH |