KE8300B Three phase Meter Test Equipment
Accuracy : 0.02 , Used for the test of standard meter and mounted meter with a accuracy class below 0.1, Number of meter position : 3-12
Features:
- High accuracy: 0.02%
- Integrated / separated aluminum alloy structure, light and reliable, flexible choices
- Meter positions can be chosen from 3-12
- Auto protection of short circuit of voltage, open circuit of current, and overload.
- Test of neutral current (optional)
- Full automatic, semi automatic and manual operation available
- Supporting bar code input, which increase the efficiency of input
- Simultaneous test of the meters with same specification, different constants and different classes.
- Forward and reverse active energy/ Forward and reverse reactive energy error test
- Creeping and starting test
- Standard deviation, 24 hour variation test
- Timing error test
- Influencing quantity test of voltage, frequency, harmonic
- Calibration and verification of constant
- Register indicating value, register combination error test
- Powerful computer management system, easy and user-friendly
- Perfect database management makes the storage, searching, and viewing of the data possible, and the data can be converted and exported in other forms
Functions:
- Base error test
- Forward / reverse active energy error test
- Forward / reverse reactive energy error test
- Creeping test (no load test)
- Starting test
- Verification of constant
- Balanced and imbalanced load test
- Dial test (energy accumulation test)
- Error repeatability test
- Standard deviation test
- 24-hour variation test
- Influencing shelf-heating test
- Reversed phase sequence test
- Influencing quantity test of voltage, frequency, harmonic
- Voltage dips and short interruptions test
- Register indicating value, register combination error test
- Timing error test (optional)
Technical Specifications:
| KE8300B-3 | KE8300B-6 | KE8300B-12 |
Number of meter position | 3 | 6 | 12 |
Accuracy | ±0.02% |
Voltage output |
Output range (P-N) | 3×(24V - 300V) |
Output power of voltage | 3×200VA | 3×200VA | 3×400VA |
Resolution | Better than ± 0.001% |
Stability | Better than ± 0.002% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.05% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Current output |
Output range | 1mA - 120A |
Output power of current | 3×150VA | 3×300VA | 3×600VA |
Resolution | Better than ± 0.001% |
Stability | Better than ± 0.002% / 150s |
Load regulation rate | Better than ± 0.01% |
Distortion factor | Better than ± 0.05% (linear resistance load) |
Harmonics output | 2nd -21st free programmable |
Phase output |
Output range | 0 -- 360° |
Resolution | ± 0.01° |
Frequency |
Output range | 45Hz – 65Hz |
Resolution | ± 0.001Hz |
Operation condition |
Power supply | 220V±10%,50/60Hz±2Hz |
Temperature | -10°C -- +40°C |
Humidity | 35% -- 85%RH |